TowardPi
BMizar






Description
Ultra Wide Field Full Range Swept Source OCT, Next Generation
- Scan speed: 400.000 A-Scans / sec
- Retina max scan (length X depth): 24 x 6 mm
- Anterior segment max scan (length X depth): 24 x 6 mm
- OCT-A max. single scan size (Retina): 24 X 20 mm
Full Range Retina OCT
- From posterior Vitreous to the Choroid-sclera
- 24 mm to 6 mm retina scan
- Automatic layer detection, segmentation and measurement of every layer of the retina and choroid
- Single line, Cross line, Grid Scan & Raster Scan
- SLO Fundus Image
Full range Anterior segment
- 24 mm to 6 mm scan
- Automatic identification of sclera spur and angle recess
- Anterior segment & AC Angle measurements
- Single line, HD Radial (8 lines) AS Radial (72 lines)
- Corna mapping: Pachymetry Map, Epithelium Map & Stroma Thickness Map (BL – Endothelium)
Ultra Wide Field OCT-A & En-Face OCT
- 3X3 mm, 6X6 mm, 12x12 mm, 15X15 mm
- Ultra Wide Field 24X20 mm in one shot
- Fast Acquisition speed (7-15 seconds)
- Automatic segmentation in 7 layers: Vitreous, Superficial Vascular, Deep Vascular Complex, Retinal Vascular Layer, Avascular layer, Choroidal capillary layer, Choroidal vascular layer & Customizable segmentation
AI Based Choroid OCT-A with quantification tools
- Choroid: OCT-A, Vessel Index, Vessel Density, Vessel volume ratio (CVV/a), Vessel volume ratio (CSV/a), Choroidal Stroma Index
Retinal Blood Flow with quantification
- Non-perfusion identification
- FAZ parameters
- Flow area vitreous neovascularization
- MNV Flow Area Follow-up
- Flow density: Grids & ETDRS rings
Comprehensive Glaucoma Analysis with enhanced iHealth
- 6x6mm Optical Nerve Head and Retinal Nerve Fiber Layer analysis resulting in cup area, rim area and cup/disc ratio
- 7x7mm Ganglion Macula Analysis measures the distance from internal limiting membrane (ILM) to outer inner plexiform layer IPL, which composes the inner 3 layers of the retina (NFL, ganglion cell layer (GCL) and inner plexiform layer), with significance map (GMA thickness vs. normative database).
- 6x6mm Disc with OCTA for blood flow analysis and density measurement of the blood vessels in the macula
- 15x9mm 3D scan for iHealth report for comprehensive analysis of the disc and macula
- Visualization of the pores of the lamina cribrosa
iSpot for PRP Laser management
- Unique solution to guide you in your photocoagulation treatment and evaluation
- Distinctive overlay of a retinal blood flow image with an en-face view highlighting laser treatment spots
SLO fundus imaging
- Scanning Laser Ophthalmoscopy fundus imaging
3D OCT(-A) Retina, Optic Disc & AS
- Blood vessel visualization and quantification in all three zones
- Automatic Parameter measurement of thickness and angles in anterior segment
- Fundus Curvature measurement
Features:
- Scan speed: 400.000 A-Scans / sec
- Retina max scan (length X depth): 24 x 6 mm
- Anterior segment max scan (length X depth): 24 x 6 mm
- Fundus Imaging: SLO (Scanning Laser Ophthalmoscope)
- Min. pupil diameter: 2 mm
- Eye Tracking Speed: 128 Hz
- OCT-A max. single scan size (Retina):24 X 20 mm
- OCT-A max. single scan size (Anterior Segment): 18 x 18 mm
- OCT-A max. resolution (single scan): 1536 x 1280
- Anterior Segment quantification
- Thickness & Volume measurements: retina & choroid
- Glaucoma analysis: GMA, ONH, iHealth & Angle measurements
- Blood flow quantification: retina, choroid, optic disk and anterior segment
- Posterior curvature retina
- 3D structure & 3D vessels